Report: Geismar plant explosion caused by ruptured reboiler - KPLC 7 News, Lake Charles, Louisiana

Report: Geismar plant explosion caused by ruptured reboiler

Posted: Updated:
GEISMAR, LA (WAFB) -

Williams Olefins has released a preliminary report on the cause of a deadly explosion at its Geismar plant in June.

According to reports, the fire was result of a rupture in an off-line reboiler that was in standby mode, next to a boiler that was in operation.

The company says three things contributed to the explosion:

- The unexpected presence of liquid hydrocarbons in the reboiler in standby mode.
- The introduction of heat into the standby reboiler.
- The pressure relief system was isolated from the reboiler which was in standby mode.

When the standby reboiler ruptured, a vapor cloud was released, then ignited by an unknown source.

Two people were killed and 77 others were injured as a result of the explosion.

OSHA and the U.S. Chemical Safety Board are also investigating the incident.

Copyright 2013 WAFB. All rights reserved.